Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X401 from the PCB
Measurement:
Test 1:
Measure the resistance on the harness connections as below.
The resistance should conform approximately to the table below:
Test 2:
Measure the Resistance between each of the following wires to earth:
Measure the resistance on the harness connections as below.
The resistance should conform approximately to the table below:
| Leads | Resistance | Brown(8)-Blue(7) | 18.8kOhms |
| Blue(7)-Black(6) | 33.7kOhms |
| Brown(8)-Black(6) | 14.9kOhms |
Test 2:
Measure the Resistance between each of the following wires to earth:
| Leads | Resistance in Ohms | Brown(8) | 1 MOhm or greater |
| Blue(7) | 1 MOhm or greater |
| Black(6) | 1 MOhm or greater |
| Green(5) | 1 MOhm or greater |

Isolate as per TOPs P4
and refit as necessary