Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect connector X401 from the PCB

Measurement:

Test 1:
Measure the resistance on the harness connections as below.
The resistance should conform approximately to the table below:
LeadsResistance
Brown(8)-Blue(7)18.8kOhms
Blue(7)-Black(6) 33.7kOhms
Brown(8)-Black(6)14.9kOhms

Test 2:
Measure the Resistance between each of the following wires to earth:
LeadsResistance in Ohms
Brown(8)1 MOhm or greater
Blue(7) 1 MOhm or greater
Black(6)1 MOhm or greater
Green(5)1 MOhm or greater