Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove Connector X3 from the PCB
Remove diverter valve head from body
Remove diverter valve head from body
Measurement:
Test 1:
If the spindle is extended test between pins 5 and 7.
Expect approximately 6 - 8.5Kohms.
If the spindle is retracted test between pins 5 and 6.
Expect approximately 6 - 8.5Kohms.
If the spindle is not fully in one position test between
pins 5 & 6 then 5 & 7.
Expect approximately 6 - 8.5Kohm.
Test 2
Measure the resistance between pins 5, 6 and 7 to earth.
Expected resistance on each test 1 MOhm or greater.
If the spindle is extended test between pins 5 and 7.
Expect approximately 6 - 8.5Kohms.
If the spindle is retracted test between pins 5 and 6.
Expect approximately 6 - 8.5Kohms.
If the spindle is not fully in one position test between
pins 5 & 6 then 5 & 7.
Expect approximately 6 - 8.5Kohm.
Test 2
Measure the resistance between pins 5, 6 and 7 to earth.
Expected resistance on each test 1 MOhm or greater.

Isolate as per TOPs P4
and refit as necessary