Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
Selector switch to DHW and CH position
CH temperature selector to maximum
DHW temperature selector to minimum
Selector switch to DHW and CH position
CH temperature selector to maximum
DHW temperature selector to minimum
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the second terminal from the bottom and the neutral on the terminal block.
Note:
If no external controls are fitted ensure there is a link fitted to the terminal block. (Link is between bottom two terminals.)
Note:
If no external controls are fitted ensure there is a link fitted to the terminal block. (Link is between bottom two terminals.)

Isolate as per TOPs P4
and refit as necessary