Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach FGA temperature clamps to the primary heat exchangers flow and return pipes as indicated by the red arrows
DHW flow rate of 12 litres/minute
Attach a U gauge to burner pressure test point
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow DHW to run for a few minutes.
Expect a differential temperature of 20°C or less.
Also monitor the burner pressure, it should remain steady and not modulate down prematurely before the hot water temperature is reached.
Is the differential as expected?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.