Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach pressure gauge to gas valve outlet pressure test point
Selector switch to DHW position
CH temperature selector to minimum
DHW Preheat selector to Off position
Selector switch to DHW position
CH temperature selector to minimum
DHW Preheat selector to Off position
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow fan to run and burner to ignite and establish.
Is the burner pressure approximately 12.5 mb?
Disconnect one lead from the modureg and make safe.
Mains Power ON.
Allow fan to run and burner to ignite and establish.
Is the burner pressure approximately 1.8 mb?
Is the burner pressure approximately 12.5 mb?
| Isolate Mains Power to appliance as per TOP's P4 |
Mains Power ON.
Allow fan to run and burner to ignite and establish.
Is the burner pressure approximately 1.8 mb?
Isolate as per TOPs P4
and refit as necessary