Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Selector switch to DHW position
CH temperature selector to minimum
DHW temperature control to maximum
Unscrew the gas valve lead from the gas valve
and reattach the opposite way round as shown
Selector switch to DHW position
CH temperature selector to minimum
DHW temperature control to maximum
Unscrew the gas valve lead from the gas valve
and reattach the opposite way round as shown
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Allow fan to run and ignition sequence to commence.
During the sparking stage of the ignition sequence, measure the voltage between the two outer pins of the gas valve connector.
Approx 210 - 230 VDC expected.
During the sparking stage of the ignition sequence, measure the voltage between the two outer pins of the gas valve connector.
Approx 210 - 230 VDC expected.

Isolate as per TOPs P4
and refit as necessary