Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Ensure appliance is cool
Reset the overheat thermostat by pushing in the button on the thermostat
Ensure appliance is cool
Reset the overheat thermostat by pushing in the button on the thermostat
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Now the overheat has been reset does the fan run?
Please select from the options below:
Overheat resets and fan now runs - Investigate cause of overheat
Overheat resets but fan still does not run
Overheat button will not push in - Replace overheat thermostat
Please select from the options below:
Overheat resets and fan now runs - Investigate cause of overheat
Overheat resets but fan still does not run
Overheat button will not push in - Replace overheat thermostat