Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector M3 from the PCB
Measurement:
Test 1.
Set Clock to OFF position.
Measure the resistance across connections
17 and 19 (black leads) at the disconnected connector.
Resistance should be open circuit.
Test 2.
Set Clock to ON position.
Measure the resistance across connections
17 and 19 (black leads) at the disconnected connector.
Resistance should be closed circuit.
Set Clock to OFF position.
Measure the resistance across connections
17 and 19 (black leads) at the disconnected connector.
Resistance should be open circuit.
Test 2.
Set Clock to ON position.
Measure the resistance across connections
17 and 19 (black leads) at the disconnected connector.
Resistance should be closed circuit.

Isolate as per TOPs P4
and refit as necessary