Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Selector switch to DHW position
CH temperature selector to minimum
DHW temperature selector to maximum
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset as required. Allow fan to run and ignition sequence to
commence then at the sparking stage of the ignition sequence:
 
Test 1:
Measure the voltage between connections 21 (grey wire)
and 22 (brown wire) at connector M4 on the PCB.
 
Voltage should be 20-70V DC.
Test 2:
Measure the voltage between connections 23 (yellow wire)
and 24 (white wire) at connector M4 on the PCB.
 
Voltage should be 70-140V DC.
 
Note:
Voltage will only be present for approximately 10 seconds, boiler may go to lockout. Reset appliance and retest as necessary.