Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Remove DC electrical connector from fan assembly and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset boiler if required.
Measure the DC volts at the PCB connector X5 from each wire
listed in the table to the black wire (pin 4) on the PCB X5 connector.
Voltages should be approx. as follows:
Lead
DC Volts
Pink (pin 6)
4.6V
Yellow (pin 5)
5V

Note:
Wires may be multicoloured.