Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove detection electrode connection FA2
from the PCB & make safe
from the PCB & make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for A/C voltage between the detection electrode PCB terminal FA2 and a suitable earth.
Expected voltage approximately 91 vac.
Expected voltage approximately 91 vac.

Isolate as per TOPs P4
and refit as necessary