Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN1 from the PCB
Measurement:
Test 1.
Measure for resistance across blue and brown of connector CN1.
Expected resistance approximately 270 kOhms.
Test 2.
Measure for resistance across brown (CN1) and a suitable earth connection.
Expected resistance greater than 1Mohm.
Measure for resistance across blue and brown of connector CN1.
Expected resistance approximately 270 kOhms.
Test 2.
Measure for resistance across brown (CN1) and a suitable earth connection.
Expected resistance greater than 1Mohm.

Isolate as per TOPs P4
and refit as necessary