Adjust, Service, Repair or Replace as necessary
Isolate Water and Gas as appropriate
Location:
Resistance tests have revealed no reason for fuse/s failure. Replace fuse/s (correctly rated fuse/s only) if it fails again, it may be that a boiler component fails during operation i.e. pump, fan, PCB etc. If during boiler operation the fuse/s do fail, observe at what point during the sequence failure occurred, this will give an indication as to the possible component causing fuse/s failure.
| Isolate Mains Power to appliance as per TOPs P4 |
Location:
Upon completion of the fault diagnostics carry out final electrical safety tests and checks as per TOPs (C6).
Refer to ADAPT for further information.
Please leave Feedback about this diagnosis via: