Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between pin 6 (violet)
at CN9 to a suitable earth point.
Voltage should be approximately 2.7V DC.
Note:
At lower flow rates voltage may fluctuate slightly.
at CN9 to a suitable earth point.
Voltage should be approximately 2.7V DC.
Note:
At lower flow rates voltage may fluctuate slightly.