Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect CN10 at PCB
Disconnect CN10 at PCB
Measurement:
Check resistances are approximately as per the table:
| Wires | Resistance |
| Red to Blue | 13kOhms | Red to Pink | 24kOhms | Red to Grey | Greater than 1MOhm | Pink to Blue | 37kOhms | Pink to Grey | Greater than 1MOhm | Blue to Grey | Greater than 1MOhm |

Isolate as per TOPs P4
and refit as necessary