Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the brown and blue wires at the top of the mains terminal block.
Note:
It is important to test at the upper side of the terminal block as this is before the internal fuse.
Note:
It is important to test at the upper side of the terminal block as this is before the internal fuse.

Isolate as per TOPs P4
and refit as necessary