Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove electrical connections from pump assembly
Measurement:
Test 1.
Measure for resistance across live and neutral terminals of the pump.
Expected resistance greater than 1Mohm (see note).
Test 2.
Measure for resistance across live and earth terminals of the pump.
Expected resistance greater than 1Mohm.
Measure for resistance across live and neutral terminals of the pump.
Expected resistance greater than 1Mohm (see note).
Test 2.
Measure for resistance across live and earth terminals of the pump.
Expected resistance greater than 1Mohm.

Isolate as per TOPs P4
and refit as necessary