Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Reconnect X6 at the PCB if you have not already done so
Unplug electrical connector at flow turbine and make safe
Unplug electrical connector at flow turbine and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between pin 4 (red)
and pin 5 (black) on connector X6.
Is approximately 5V DC present?
Note:
Wires may be multicoloured.
and pin 5 (black) on connector X6.
Is approximately 5V DC present?
Note:
Wires may be multicoloured.

Isolate as per TOPs P4
and refit as necessary