Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Move wire back to connection 5 if you have not already done so
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC voltage between pin 5 at the spark generator and a suitable earth point.
Expected voltage is approximately 100V AC.
Expected voltage is approximately 100V AC.

Isolate as per TOPs P4
and refit as necessary