Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Remove DC electrical connector from fan assembly and make safe
Pull connector X5 back slightly to expose test points
Preheat OFF
Pull connector X5 back slightly to expose test points
Preheat OFF
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Reset boiler if required.
Measure the DC volts at the PCB connector X5 on the
harness from each wire listed in the table to the
black wire (pin 4) on the PCB X5 connector.
Voltages should be approx. as follows:
Note:
Wires may be multicoloured.
Measure the DC volts at the PCB connector X5 on the
harness from each wire listed in the table to the
black wire (pin 4) on the PCB X5 connector.
Voltages should be approx. as follows:
Note:
Wires may be multicoloured.

Isolate as per TOPs P4
and refit as necessary