Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Selector switch set to DHW
DHW temperature control set to MAX
Preheat switched OFF
Attach temperature clamps to flow and return pipes
DHW temperature control set to MAX
Preheat switched OFF
Attach temperature clamps to flow and return pipes
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow appliance to operate for hot water and reach temperature.
Monitor the temperature differential across flow and return pipes.
Expected temperature differential approximately 28°C or less.
Note.
Flow rate no greater than 14.5 litres/min.
Monitor the temperature differential across flow and return pipes.
Expected temperature differential approximately 28°C or less.
Note.
Flow rate no greater than 14.5 litres/min.