Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Selector switch set to DHW
DHW temperature control set to MAX
Preheat switched OFF
Attach pressure gauge to the gas inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and ignition sequence to commence.
Does the pressure gauge show an inlet pressure of 14 mb or greater
throughout the operation?
Note:
1. The manufacturer states the boiler range is able to deliver it's full output at
inlet pressures as low as 14mb, however please refer to British Gas Technical Operational Procedures for further guidance regarding gas inlet working pressures.
2. When "U" gauge is removed test point should be tightened and checked for gas tightness.