Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Selector switch set to DHW
Preheat switched OFF
Selector switch set to DHW
Preheat switched OFF
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
With a hot water tap open (flow rate greater than 2.5 ltr/min).
Measure for DC voltage across pin 9 (X8 connector PCB) and main neutral (terminal block).
Expected voltage approximately 1.9 - 2.5 Vdc.
Measure for DC voltage across pin 9 (X8 connector PCB) and main neutral (terminal block).
Expected voltage approximately 1.9 - 2.5 Vdc.