Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use insulation mat as required)
Pull connector X1 back slightly to expose test points
Pull connector X1 back slightly to expose test points
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC volts between pin 5 (brown)
and pin 6 (blue) at connector X1 on the PCB.
Mains voltage should be present.
and pin 6 (blue) at connector X1 on the PCB.
Mains voltage should be present.

Isolate as per TOPs P4
and refit as necessary