Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Gain access to control PCB

Measurement:

Measure the resistance across the center and left pins of the Hot Water potentiometer (located on the display PCB).
The resistances measured will alter as potentiometer is turned and should conform (approximately) with the readings below.
Setting
Ohms
Minimum
2.5
Medium
3.5K
Maximum
2.5K

Note:
Ensure a good connection is made.