Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Water Off
Drain off excess water through hot tap
Drain off excess water through hot tap
Observation:
Inspect the flow regulator/filter for blockages or damage.
Note:
Flow regulator/filter is located on the DHW inlet isolating valve. The filter restrictor can only be removed when the Isolator valve is in the fully off position (slot across the valve) the filter will be damaged if removal is attempted with valve not in the fully closed position.
Note:
Flow regulator/filter is located on the DHW inlet isolating valve. The filter restrictor can only be removed when the Isolator valve is in the fully off position (slot across the valve) the filter will be damaged if removal is attempted with valve not in the fully closed position.
Isolate as per TOPs P4
and refit as necessary