Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect flame sense lead from the electrode
Remove connector X2B from the PCB
Remove connector X2B from the PCB
Measurement:
Check for continuity (zero resistance) between the electrode end of the lead to the black wire on X2B.
Check that the lead and connectors are in good condition and are able to fit securely onto the electrode / PCB.
Check that the lead and connectors are in good condition and are able to fit securely onto the electrode / PCB.

Isolate as per TOPs P4
and refit as necessary