Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Selector switch set to Hot Water position
Gain access to PCB, use isolation mat as required
Gain access to PCB, use isolation mat as required
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC volts across ON/OFF switch (test point as illustrated) and a suitable earth connection.
Expected voltage 2.4 - 3.4 VDC.
Note.
Voltage measured does fluctuate slightly.
Expected voltage 2.4 - 3.4 VDC.
Note.
Voltage measured does fluctuate slightly.

Isolate as per TOPs P4
and refit as necessary