Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Preheat OFF
Gain access to PCB (use insulation mat as required)
Run Hot Water Tap at 3 l/min
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage between pin 8 (black) and pin 9 (blue) on connector X8.
Expect approximately 2.5vdc.
Note:
To ensure a good connection use the small test points just below the connector.