Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Preheat OFF
Gain access to PCB (use insulation mat as required)
Gain access to PCB (use insulation mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC volts at PCB connector X3 from the brown wire (pin 1) and blue wire (pin 2) to Earth.
The voltage measured should conform to the table below:
The voltage measured should conform to the table below:
| Wire | Expected Voltage |
| Brown to Earth | Approx. 240v |
| Blue to Earth | Less than 15v |