Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Unplug the harness from the side of the pump and remove the pumps electrical cover

Measurement:

Test 1.
Measure the resistance between the L and N terminals of the pump.
Expected resistance approximately 160 Ohms.
Test 2.
Measure for resistance between pin 5 (brown) on connector X1 and a suitable earth connection.
Expected resistance greater than 1 MOhm (or O.L).
Expect approximately 160 Ohms.