Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB
Remove X3 connector from the PCB
Remove X3 connector from the PCB
Measurement:
Test 1.
Measure for resistance across the brown & blue wires of connector X3.
Expected resistance greater than 1 MOhm.
Test 2.
Measure for resistance across the brown wire of connector X3 and a suitable earth connection.
Expected resistance greater than 1 MOhm.
Measure for resistance across the brown & blue wires of connector X3.
Expected resistance greater than 1 MOhm.
Test 2.
Measure for resistance across the brown wire of connector X3 and a suitable earth connection.
Expected resistance greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary