Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB
Disconnect plug X1C from PCB (3 way plug 3rd from left)
Disconnect plug X1C from PCB (3 way plug 3rd from left)
Measurement:
Test 1:
Measure the resistance between the blue and brown wires at X1C.
Expected resistance greater than 1MOhm (or O.L).
Test 2:
Measure for resistance between the brown wire at X1C to a suitable earth point.
Expected resistance greater than 1MOhm (or O.L).
Measure the resistance between the blue and brown wires at X1C.
Expected resistance greater than 1MOhm (or O.L).
Test 2:
Measure for resistance between the brown wire at X1C to a suitable earth point.
Expected resistance greater than 1MOhm (or O.L).

Isolate as per TOPs P4
and refit as necessary