Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the mains connector from the Spark Generator
Measurement:
Test 1.
Measure for resistance across the pins 1 & 2 of spark generator connector.
Expected resistance greater than 1 MOhm.
Test 2.
Measure for resistance across pin 1 spark generator connector and a suitable earth connection.
Expected resistance greater than 1 MOhm.
Measure for resistance across the pins 1 & 2 of spark generator connector.
Expected resistance greater than 1 MOhm.
Test 2.
Measure for resistance across pin 1 spark generator connector and a suitable earth connection.
Expected resistance greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary