Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Gas Off
Attach pressure gauge to the inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow the ignition sequence to commence.
A pressure change should be seen on the gauge.
A slight drop then a return to working pressure should be seen as the gas valve opens.
Note:
When U-gauge is removed the pressure test point
should be tightened & checked for gas soundness.