Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Boiler mains switch ON
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage across the red and yellow leads at the diverter valve connector. Access to connector is best from underneath the boiler.
Actuator is shown disconnected for illustration purposes only.
Mains voltage should be present.
Note:
Grey lead fitted but not used on this version.
Actuator is shown disconnected for illustration purposes only.
Mains voltage should be present.
Note:
Grey lead fitted but not used on this version.

Isolate as per TOPs P4
and refit as necessary