Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Gas Off
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Use Insulation mat as required
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow ignition sequence to commence.
Measure the voltage at the 2 way connector on the brown and blue wires at the spark generator.
During the sparking phase of ignition expect a voltage of approximately 200 - 240 Vac.
Note:
Reset as necessary until test is complete.