Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the pump connector from the PCB
Measurement:
Test 1:
Measure the resistance between the brown and pink wires on the pump connector.
Expect a resistance of between approximately 145 and 250 ohms.
Test 2:
Measure the resistance between the brown wire and a suitable earth.
Expect a resistance of at least 1 MOhm or greater.
Measure the resistance between the brown and pink wires on the pump connector.
Expect a resistance of between approximately 145 and 250 ohms.
Test 2:
Measure the resistance between the brown wire and a suitable earth.
Expect a resistance of at least 1 MOhm or greater.

Isolate as per TOPs P4
and refit as necessary