Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove flame detection electrode from its housing
Measurement:
Thoroughly check the electrode for signs of damage, corrosion, cracked ceramic insulation and also that it is clean.
Also measure the resistance across the electrode, expect continuity / zero resistance.
Refit electrode after test.
Note:
Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary.
Also measure the resistance across the electrode, expect continuity / zero resistance.
Refit electrode after test.
Note:
Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary.

Isolate as per TOPs P4
and refit as necessary