Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between pin 2 (brown) and pin 3 (blue) on connector J2 at the control PCB.
Mains voltage should be measured.
Note:
Up to 140V AC may be present without a demand.
Only pass this test if full mains voltage is present.
Mains voltage should be measured.
Note:
Up to 140V AC may be present without a demand.
Only pass this test if full mains voltage is present.

Isolate as per TOPs P4
and refit as necessary