Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Attach pressure gauge to gas valve pressure outlet test point
Turn dip switch 3 at bottom left of the
control PCB to the "off" (down) position
Attach pressure gauge to gas valve pressure outlet test point
Turn dip switch 3 at bottom left of the
control PCB to the "off" (down) position
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
When the burner ignites is the burner pressure approximately 6mb?
Notes:
1. When pressure gauge is removed the pressure test point
should be tightened and checked for gas tightness.
2. Put dip switch 3 back into "on" (up) position after test.
Notes:
1. When pressure gauge is removed the pressure test point
should be tightened and checked for gas tightness.
2. Put dip switch 3 back into "on" (up) position after test.
Isolate as per TOPs P4
and refit as necessary