Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
Hot Water Tap OFF
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance as necessary.
Test 1:
Measure the voltage between pin 9 (red)
and pin 10 (black) on connector J7 at the control PCB.
Voltage should be approximately 5V DC or greater.
Test 2:
Turn hot water tap ON.
As before measure the voltage between pin 9 (red)
and pin 10 (black) on connector J7 at the control PCB.
Shortly after the pump begins to run the
voltage should drop to approximately 0V DC.