Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and burner to ignite and establish.
Monitor the voltage between pin 2 (brown) and pin 3 (blue) on connector J2 at the control PCB.
When the burner extinguishes is mains voltage still present, or does it disappear or lower as the burner extinguishes?
Note:
Voltage change may only be brief. Repeat test as required.