Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach temperature probes to the flow and return pipes as indicated
DHW Temperature Selector set to MA
Set flow rate to approximately 11.7 l/min
DHW Temperature Selector set to MA
Set flow rate to approximately 11.7 l/min
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as necessary.
Allow the burner to light and establish.
Monitor the temperature differential between the
flow and return pipes for at least 2 minutes.
The differential should be approximately 25°C or lower.
Allow the burner to light and establish.
Monitor the temperature differential between the
flow and return pipes for at least 2 minutes.
The differential should be approximately 25°C or lower.