Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X6b from the PCB
Measurement:
Test 1:
Measure the resistance between pin 4 (middle brown) and pin 5 (middle blue) wires on X6b connector.
Resistance should be approximately 160 Ohms or greater.
Test 2:
Measure the resistance between pin 4 (middle brown) on X6b connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between pin 5 (middle blue) on X6b connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between pin 4 (middle brown) and pin 5 (middle blue) wires on X6b connector.
Resistance should be approximately 160 Ohms or greater.
Test 2:
Measure the resistance between pin 4 (middle brown) on X6b connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between pin 5 (middle blue) on X6b connector to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary