Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect leads from Gas Valve
Measurement:
Test 1:
Measure resistance across the two outer pins on the gas valve.
Expect a resistance of approx. 4 kOhms.
Test 2:
Measure the resistance between the centre pin of the gas valve and one of the outer pins.
Expect a resistance of 1 MOhm or greater.
Measure resistance across the two outer pins on the gas valve.
Expect a resistance of approx. 4 kOhms.
Test 2:
Measure the resistance between the centre pin of the gas valve and one of the outer pins.
Expect a resistance of 1 MOhm or greater.

Isolate as per TOPs P4
and refit as necessary