Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Water OFF
Drain off excess water through hot tap
Drain off excess water through hot tap
Observation:
Inspect the flow regulator/filter for blockages or damage.
Note:
Flow regulator/filter is located on the DHW inlet isolating valve. The filter restrictor can only be removed when the isolator valve is in the fully off position (slot across the valve) - the filter will be damaged if removal is attempted with valve not in the fully closed position.
Note:
Flow regulator/filter is located on the DHW inlet isolating valve. The filter restrictor can only be removed when the isolator valve is in the fully off position (slot across the valve) - the filter will be damaged if removal is attempted with valve not in the fully closed position.
Isolate as per TOPs P4
and refit as necessary