Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
NO demands for CH or HW
Disconnect DHW thermistor at harness lead
Gain access to main terminal box
On/Off Switch ON
Disconnect DHW thermistor at harness lead
Gain access to main terminal box
On/Off Switch ON
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltages between the fan connectors
(as per the table below) and the Neutral (blue) at the incoming mains connector.
The voltages should conform approximately to the table below:
(as per the table below) and the Neutral (blue) at the incoming mains connector.
The voltages should conform approximately to the table below:
| Wire | DC Volts | Pink | 110 |
| Yellow | 94 |
| Black | 110 |

Isolate as per TOPs P4