Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the ON/OFF switch at the inline connector
(as highlighted opposite)
(as highlighted opposite)
Measurement:
Test 1:
Turn the ON/OFF switch OFF.
Measure the resistance between the red
and brown wires.
Expected resistance open circuit.
Test 2:
Turn the ON/OFF switch ON.
Measure the resistance between the red
and brown wires.
Expected resistance short circuit.
Turn the ON/OFF switch OFF.
Measure the resistance between the red
and brown wires.
Expected resistance open circuit.
Test 2:
Turn the ON/OFF switch ON.
Measure the resistance between the red
and brown wires.
Expected resistance short circuit.

Isolate as per TOPs P4