Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach U-gauge to burner pressure test point
(Upper of the two ports on the right hand side by the solenoid)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow fan to run and burner to ignite
Is the burner pressure approximately 13.2 mbar?
Note:
When U-gauge is removed the pressure test point should be tightened & checked for gas soundness.